Dual Output 30V-30V 70W Equipment Switching Power Supply
Features:
· Huyssen Dual Output Power Supply
· Universal AC input : 90-264V
· Protections: Short circuit / Overload / Over voltage / over current
· Cooling by free air convection
· High efficiency, long life and high reliability
· All using 105°C long life electrolytic capacitors
· High operating temperature up to 70°C
· LED indicator for power on
· 100% full load burn-in test
· 24 months warranty
Specifications:
MODEL |
HSJ-70-3030 |
HSJ-70-0512 |
HSJ-70-1212 |
||||
OUTPUT |
OUTPUT NUMBER |
CH1 |
CH2 |
CH1 |
CH2 |
CH1 |
CH2 |
DC VOLTAGE |
-30V |
30V |
5V |
12V |
-12V |
12V |
|
RATED CURRENT |
0.3A |
2A |
4A |
4A |
2A |
5.6A |
|
RATED POWER |
70W |
70W |
70W |
||||
RIPPLE&NOISE |
300mVp-p |
300mVp-p |
80mVp-p |
240mVp-p |
300mVp-p |
120mVp-p |
|
VOLTAGETOLERANCE |
±2.0% |
±6.0% |
±2.0% |
±5.0% |
±4.0% |
±4.0% |
|
LINEREGULATION |
±0.5% |
±1.5% |
±0.5% |
±1.0% |
±0.5% |
±0.5% |
|
LOADREGULATION |
±0.5% |
±3.0% |
±0.5% |
±2.0% |
±3.0% |
±3.0% |
|
SETUP.RISEHOLD.TIME |
500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load |
||||||
HOLD TIME |
80ms/230VAC 16ms/115VAC at full load |
||||||
INPUT |
VOLTAGE RANGE |
90 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) |
|||||
FREQUENCYRANGE |
47~63HZ |
||||||
EFFICIENCY |
84% |
78% |
82% |
||||
AC CURRENT |
0.8A/115VAC 0.55A/230VAC |
||||||
INRUSH CURRENT |
COLD START 36A/230VAC |
||||||
LEAKAGECURRENT |
<2mA/240VAC |
||||||
PROTECTION |
OVERLOAD |
110~150% rated output power |
|||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed |
|||||||
OVER VOLTAGE |
YES |
YES |
|||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||||||
ENVIRONMENT |
WORKING TIMP |
-25~+70°C (Refer to "Derating Curve") |
|||||
WORKINGHUMIDITY |
20~90% RH non-condensing |
||||||
STORAGE TEMP HUMIDITY |
-40~+85°C 10~95%RH |
||||||
TEMPCOEFFICIENT |
±0.03%/ °C(0~50°C) on CH1 output |
||||||
VIBRATION |
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes |
||||||
SAFETY&EMC |
SAFETYSTANDARDS |
U60950, TUV EN60950 approved |
|||||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
||||||
ISOLATIONRESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH |
||||||
EMC EMISSION |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 |
||||||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A |
||||||
QTHERS |
MTBF |
179Khrs min. MIL-HDBK-217F (25°C ) |
|||||
DIMENSION |
88*70*38mm (L*W*H) |
||||||
PACKING |
0.4Kg; 30PCS/9Kg |
Applications:
Industrial control equipment, self-service terminal equipment, medical equipment, communication equipment, animation products, game consoles, beauty equipment, etc.