AC 90-264V DC 12V 8.3A 100W Switching Power supply
Features:
Huyssen Power Supply 12V8.3A
AC input : 90~264VAC
Low leakage current <2mA
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by air
Withstand 300vac surge input for 5 second
Conformal coated
LED indicator for power on
Low cost, high reliability
100% full load burn-in test
2 years warranty
Specifications:
MODEL |
HSJ-100-12 |
|
OUTPUT | DC VOLTAGE | 12V |
RATED CURRENT | 8.3A | |
CURRENT RANGE | 0 ~ 8.3A | |
RATED POWER | 100W | |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | |
VOLTAGE ADJ. RANGE | ±10% | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±2.0% | |
SETUP, RISE TIME | 2500ms, 50ms/230VAC | |
HOLD UP TIME (Typ.) | 20ms/230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 264VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 83% | |
AC CURRENT (Typ.) | 0.9A/230VAC 0.45A/230VAC | |
INRUSH CURRENT(Typ.) | 30A/230VAC | |
LEAKAGE CURRENT | <2mA / 240VAC | |
PROTECTION | OVER LOAD | 105 ~ 140% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 115%~150% |
|
Protection type :Hiccup mode, recovers automatically after fault condition is removed | ||
OVER TEMPERATURE | Shut down O/P voltage, recovers automatically after temperature goes down | |
ENVIRONMENT | WORKING TEMP. | -20 ~ +60°C (Refer to derating curve) |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -20 ~ +85°C , 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0~50°C) | |
VIBRATION | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY | SAFETY STANDARDS | U60950-1 approved |
WITHSTAND VOLTAGE Note 6 | I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | |
OTHERS | MTBF | 235K hrs min. MIL-HDBK-217F (25°C ) |
DIMENSION | 160*98*40mm (L*W*H) | |
PACKING | 0.45Kg; 20pcs/10Kg/0.79CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. |
Related products:
Applications:
Widely used in : Billboards, LED Lighting ,Display screen, 3D Printer, CCTV camera, Laptop, Audio ,Telecommunication ,STB , Intelligent robot, Industrial control, equipment, etc.
Production Process
Applications for power supply
Packing & Delivery
Certifications