AC to DC 150W 15V 10A PSU LRS-150-15
Features:
Huyssen Power Supply 12V12.5A
AC input 110/220VAC
Low leakage current <2mA
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by air
Withstand 300vac surge input for 5 second
Conformal coated
LED indicator for power on
Low cost, high reliability
100% full load burn-in test
2 years warranty
Specifications:
Model |
LRS-150-5 |
LRS-150-12 |
LRS-150-15 |
LRS-150-24 |
LRS-150-36 |
LRS-150-48 |
|
output |
DC voltage |
5V |
12V |
15V |
24V |
36V |
48V |
Rated current |
20A |
12.5A |
10A |
6.5A |
4.3A |
3.3A |
|
Current range |
0~20A |
0~12.5A |
0~10A |
0~6.5A |
0~4.3A |
0~3.3A |
|
Rated power |
120W |
150W |
150W |
156W |
154.8W |
158.4W |
|
Ripple&noise |
120mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
200mVp-p |
|
DC voltage ADJ. range |
±10% |
±10% |
±10% |
±10% |
±10% |
±10% |
|
Voltage tolerance Note.3 |
±3% |
±2% |
±1% |
±1% |
±1% |
±1% |
|
Line regulation Note.4 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Load regulation Note.5 |
±2% |
±1% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Setup,rise,hold up time | 800ms,30ms,40ms/230VAC(full load) | ||||||
input |
Voltage range | 90~132VAC/170~264VAC(selected by switch),240~373VDC | |||||
Frequency range | 47~63HZ | ||||||
AC current | 2.8A/115VAC 1.6A/230VAC | ||||||
Inrush current | Cold start 50A/230VAC | ||||||
Efficiency |
80% |
83% |
85% |
86% |
88% | 90% | |
Leakage current | <0.75mA/240VAC | ||||||
protection |
overload | Rated output power110%~150% start over load protection | |||||
protection type:hiccup mode,auto-recovery after fault condition is removed | |||||||
Over voltage | Rated output voltage 115%~135% Start over voltage protection | ||||||
Protection type:hiccup mode,auto-recovery after fault condition is removed | |||||||
Over temperature | 100℃±10℃(RT1 detect beside transformer) | ||||||
Protection type:cut off the output,auto-recovery after the temperature become normal | |||||||
environment | Working temp,humidity | -30℃~+70℃(Please refer to“derating curve”) 20%~90%RH Non-condensing |
|||||
Storage temp,humidity | -40℃~+85℃,10%~95%RH non-condensing | ||||||
Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes | ||||||
safety | Withstand voltage | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC | ||||||
Fit standard | Safety standards | Compliance to UL60950-1,TUV EN60950-1,GB4943 | |||||
EMC emission | Compliance to EN55022(CISPR22)Class A,GB9254 Class B,EN55014,EN61000-3-2,3 | ||||||
EMC immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61000-6-1 | ||||||
others | Dimension | 159*97*30mm(L*W*H) | |||||
Weight/packing | 0.43kg/30pcs/13.9kg/0.023m³/0.82CUFT | ||||||
MTBF | ≥580K hrs min. MIL-HDBK-217F(25℃) | ||||||
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.Load regulation is measured from 0% to 100% rated load 6.The ambient temperature derating of 5℃/1000 m is needed for operating altitude greater than 2000m(6500ft) 7.The power supply is considered as a component which will be installed into a finalequipment.The final equipment must be re-confirmed that it still meets EMC directives.For guidance on how to perform these EMC tests. |
Related products:
Applications:
Widely used in : Billboards, LED Lighting ,Display screen, 3D Printer, CCTV camera, Laptop, Audio ,Telecommunication ,STB , Intelligent robot, Industrial control, equipment, etc.