Din Rail Power Supply HDR-60-12 12V 5A 60W
Specifications:
Din Rail Power Supply |
||||||
MODEL |
HDR-60-5 |
HDR-60-12 |
HDR-60-24 |
HDR-60-36 |
HDR-60-48 |
|
OUTPUT
|
DC voltage |
5V |
12V |
24V |
36V |
48V |
Rated output current |
12A |
5A |
2.5A |
1.67A |
1.25A |
|
Output current range |
0-12A |
0-5A |
0-2.5A |
0-1.67A |
0-1.25A |
|
DC power |
60W |
60W |
60W |
60W |
60W |
|
Ripple and noise |
80mVp-p |
120mVp-p |
200mVp-p |
300mVp-p |
400mVp-p |
|
VOLTAGE ADJ. RANGE |
4.75 ~ 5.5V |
10.8 ~ 13.2V |
21.6 ~ 26.4V |
32.4 ~39.6V |
43.2 ~ 52.8V |
|
Voltage tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
|
line regulation |
±1% |
±1% |
±1% |
±1% |
±1% |
|
Load regulation |
±1% |
±1% |
±1% |
±1% |
±1% |
|
Setup,rise time |
800ms,60ms/230VAC 1000MS,30MS/115VAC at full load |
|||||
Hold up time |
50ms/230VAC 20ms/115VAC at full load |
|||||
INPUT |
AC voltage range |
AC85~265V wide range 47~63Hz |
||||
Frequency range |
47-63Hz |
|||||
Efficiency |
80% |
82% |
85% |
87% |
88% |
|
AC current |
1.5A/115VAC 0.75A/230VAC |
|||||
Inrush current |
COLD START 30A/115VAC 60A/230VAC |
|||||
Leakage current |
<1mA/240VAC |
|||||
PROTECTION |
Overload
|
Above 105% rated output power |
||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||||
Over-voltage
|
5.75-6.75V |
13.8-16.2V |
27.6-32.4V |
41.4-48.6V |
55.2-64.81V |
|
protection type:Shut down o/p voltage,re-power on tore cover |
||||||
ENVIRONMENT |
Working temp. |
-20~+60℃ |
||||
Working humidity |
20~90% RH non-condensing |
|||||
store temp.,humidity |
-40~+85℃,10~95% RH |
|||||
Temp. coefficient |
±0.03%/°C (0~50°C ) |
|||||
OTHER |
Overall dimension |
52.5*90*54.5mm 60pcs/Carton ( common packing ) |
||||
Weight |
0.18Kg |
Related products:
Applications:
Widely used in : Industrial automation, LED Lighting ,Display screen, 3D Printer, CCTV camera, Laptop, Audio ,Telecommunication ,STB , Intelligent robot, Industrial control, equipment, etc.