Dual Output 180W 24V36V Industrial Control Power Supply

Short Description:

Huyssen’s multiple output power supplies are range from 40 Watts to 600 Watts, output voltage from 5 VDC to 48VDC or higher. Dual output, triple output, and quad output are available, accept customize.

Many electronics applications & equipment require multiple voltages to supply their various internal circuits. It can save time, space, and money in some applications, please contact us for more.


Product Detail

Product Tags

Video

Features:

• Huyssen 24V36V Daul Output Voltage Power Supply

• Universal AC input / full range

• Cooling by free air convection

• All using 105°C long life electrolytic capacitors

• High operating temperature up to 70°C

• High efficiency, long life and high reliability

• LED indicator for power on

• Full load high temperature burn-in, 100% burn-in test

• Protections: Short circuit / over current / Overload / Over voltage

• 24 months warranty

180W multi output3

Specifications:

MODEL

HSJ-180-2412

HSJ-180-3624

HSJ-180-4812

OUTPUT OUTPUT NUMBER

CH1

CH2

CH1

CH2

CH1

CH2

  DC VOLTAGE

12V

24V

36V

24V

48V

12V

  RATED CURRENT

5A

5A

4A

1.5A

3A

3A

  RATED POWER

180W

180W

180W

  RIPPLE&NOISE

120mVp-p

240mVp-p

300mVp-p

200mVp-p

400mVp-p

120mVp-p

  VOLTAGETOLERANCE

±2.0%

±6.0%

±2.0%

±5.0%

±4.0%

±4.0%

  LINEREGULATION

±0.5%

±1.5%

±0.5%

±1.0%

±0.5%

±0.5%

  LOADREGULATION

±0.5%

±3.0%

±0.5%

±2.0%

±3.0%

±3.0%

  SETUP.RISEHOLD.TIME 500ms, 30ms/230VAC          1200ms, 30ms/115VAC at full load
  HOLD TIME 80ms/230VAC          16ms/115VAC at full load
INPUT VOLTAGE RANGE 88 ~ 264VAC  125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
  FREQUENCYRANGE 47~63HZ
  EFFICIENCY

86%

82%

80%

  AC CURRENT 0.8A/115VAC           0.55A/230VAC
  INRUSH CURRENT COLD START 36A/230VAC
  LEAKAGECURRENT <2mA/240VAC
PROTECTION OVERLOAD 110~150% rated output power
    Protection type: Hiccup mode,recovers automatically after fault condition is removed
  OVER VOLTAGE  YES  YES
    Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT WORKING TIMP -25~+70°C (Refer to "Derating Curve")
  WORKINGHUMIDITY 20~90% RH non-condensing
  STORAGE TEMP HUMIDITY -40~+85°C   10~95%RH
  TEMPCOEFFICIENT ±0.03%/ °C(0~50°C) on CH1 output
  VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY&EMC SAFETYSTANDARDS U60950, TUV EN60950 approved
  WITHSTAND VOLTAGE I/P-O/P:3KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
  ISOLATIONRESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
  EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
  EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
QTHERS MTBF 179Khrs min.      MIL-HDBK-217F (25°C )
  DIMENSION 140*78*40mm (L*W*H)
  PACKING 0.5Kg; 20PCS/11Kg

Dual output power supply widely used in:

LED lightings, 3D printing, Monitoring security equipment, industrial equipment, communication network, routers, motors, cameras, tablet computers, projection equipment, power amplifiers, navigation integrated machines, facial recognition, building intercom systems, etc.

Applications

Apparatus & instrument
Automatic control
Medical equipment
Military equipment
power system
beauty equipment
LCD & LED
Security monitoring system

Packing & Delivery

by plane
by ship
by truck
power supply packing 500
ready to ship

Certifications

Certifications1
Certifications8
Certifications7
Certifications2
Certifications3
Certifications5
Certifications6
Certifications4

  • Previous:
  • Next:

  • Write your message here and send it to us