Dual Output 5V12V 100W Industrial DC power supply
Features:
Huyssen dual Output Power Supply
Universal AC input : 90-264V
Protections: Short circuit / Overload / Over voltage / over current
Cooling by free air convection
High efficiency, long life and high reliability
All using 105°C long life electrolytic capacitors
High operating temperature up to 70°C
LED indicator for power on
100% full load burn-in test
24 months warranty
Specifications:
MODEL |
HSJ-100-2412 |
HSJ-100-0512 |
HSJ-100-3612 |
||||
OUTPUT | OUTPUT NUMBER |
CH1 |
CH2 |
CH1 |
CH2 |
CH1 |
CH2 |
DC VOLTAGE |
12V |
24V |
5V |
12V |
36V |
12V |
|
RATED CURRENT |
4.3A |
2A |
3A |
7A |
2A |
2.3A |
|
RATED POWER |
100W |
100W |
100W |
||||
RIPPLE&NOISE |
120mVp-p |
240mVp-p |
80mVp-p |
240mVp-p |
300mVp-p |
120mVp-p |
|
VOLTAGEADJ.RANGE |
CH1: 4.75~5.5V |
CH1: 4.75~5.5V |
CH1: 11.5 ~ 15.5V |
||||
VOLTAGETOLERANCE |
±2.0% |
±6.0% |
±2.0% |
±5.0% |
±4.0% |
±4.0% |
|
LINEREGULATION |
±0.5% |
±1.5% |
±0.5% |
±1.0% |
±0.5% |
±0.5% |
|
LOADREGULATION |
±0.5% |
±3.0% |
±0.5% |
±2.0% |
±3.0% |
±3.0% |
|
SETUP.RISEHOLD.TIME | 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load | ||||||
HOLD TIME | 80ms/230VAC 16ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE | 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | |||||
FREQUENCYRANGE | 47~63HZ | ||||||
EFFICIENCY |
86% |
82% |
80% |
||||
AC CURRENT | 0.8A/115VAC 0.55A/230VAC | ||||||
INRUSH CURRENT | COLD START 36A/230VAC | ||||||
LEAKAGECURRENT | <2mA/240VAC | ||||||
PROTECTION | OVERLOAD | 110~150% rated output power | |||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | YES | YES | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
ENVIRONMENT | WORKING TIMP | -25~+70°C (Refer to "Derating Curve") | |||||
WORKINGHUMIDITY | 20~90% RH non-condensing | ||||||
STORAGE TEMP HUMIDITY | -40~+85°C 10~95%RH | ||||||
TEMPCOEFFICIENT | ±0.03%/ °C(0~50°C) on CH1 output | ||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
SAFETY&EMC | SAFETYSTANDARDS | U60950, TUV EN60950 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATIONRESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | ||||||
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | ||||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A | ||||||
QTHERS | MTBF | 179Khrs min. MIL-HDBK-217F (25°C ) | |||||
DIMENSION | 160*98*40mm (L*W*H) | ||||||
PACKING | 0.55Kg; 20PCS/9Kg |
Applications:
Industrial control equipment, self-service terminal equipment, medical equipment, communication equipment, animation products, game consoles, beauty equipment, etc.