New Delivery for 15v 4a Power Supply - Dual Output 12V48V 250W Healthcare equipment Power Supply – Huyssen
New Delivery for 15v 4a Power Supply - Dual Output 12V48V 250W Healthcare equipment Power Supply – Huyssen Detail:
Video
Features:
1.Huyssen Daul Output Voltage Power Supply
2.Universal AC input / full range
3.Cooling by free air convection
4.All using 105°C long life electrolytic capacitors
5.High operating temperature up to 70°C
6.High efficiency, long life and high reliability
7.LED indicator for power on
8.Full load high temperature burn-in, 100% burn-in test
9.Protections: Short circuit / over current / Overload / Over voltage
10.24 months warranty
Specifications:
MODEL |
HSJ-250-2412 |
HSJ-250-3612 |
HSJ-250-4812 |
||||
OUTPUT | OUTPUT NUMBER |
CH1 |
CH2 |
CH1 |
CH2 |
CH1 |
CH2 |
DC VOLTAGE |
12V |
24V |
36V |
12V |
48V |
12V |
|
RATED CURRENT |
5A |
8A |
4A |
10A |
3A |
8A |
|
RATED POWER |
250W |
250W |
250W |
||||
RIPPLE&NOISE |
120mVp-p |
240mVp-p |
300mVp-p |
120mVp-p |
400mVp-p |
120mVp-p |
|
VOLTAGETOLERANCE |
±2.0% |
±6.0% |
±2.0% |
±5.0% |
±4.0% |
±4.0% |
|
LINEREGULATION |
±0.5% |
±1.5% |
±0.5% |
±1.0% |
±0.5% |
±0.5% |
|
LOADREGULATION |
±0.5% |
±3.0% |
±0.5% |
±2.0% |
±3.0% |
±3.0% |
|
SETUP.RISEHOLD.TIME | 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load | ||||||
HOLD TIME | 80ms/230VAC 16ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | |||||
FREQUENCYRANGE | 47~63HZ | ||||||
EFFICIENCY |
86% |
82% |
80% |
||||
AC CURRENT | 0.8A/115VAC 0.55A/230VAC | ||||||
INRUSH CURRENT | COLD START 36A/230VAC | ||||||
LEAKAGECURRENT | <2mA/240VAC | ||||||
PROTECTION | OVERLOAD | 110~150% rated output power | |||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | YES | YES | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
ENVIRONMENT | WORKING TIMP | -25~+70°C (Refer to “Derating Curve”) | |||||
WORKINGHUMIDITY | 20~90% RH non-condensing | ||||||
STORAGE TEMP HUMIDITY | -40~+85°C 10~95%RH | ||||||
TEMPCOEFFICIENT | ±0.03%/ °C(0~50°C) on CH1 output | ||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
SAFETY&EMC | SAFETYSTANDARDS | U60950, TUV EN60950 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATIONRESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | ||||||
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | ||||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A | ||||||
QTHERS | MTBF | 179Khrs min. MIL-HDBK-217F (25°C ) | |||||
DIMENSION | 160*78*40mm (L*W*H) | ||||||
PACKING | 0.8Kg; 20PCS/11Kg |
Applications:
Industrial control equipment, self-service terminal equipment, medical equipment, communication equipment, animation products, game consoles, beauty equipment, etc.
Applications for power supply
Packing & Delivery
Certifications
Product detail pictures:
Related Product Guide:
"Sincerity, Innovation, Rigorousness, and Efficiency" may be the persistent conception of our organization to the long-term to build together with shoppers for mutual reciprocity and mutual advantage for New Delivery for 15v 4a Power Supply - Dual Output 12V48V 250W Healthcare equipment Power Supply – Huyssen , The product will supply to all over the world, such as: Ireland, Indonesia, California, During in 11 years, We have participated in more than 20 exhibitions, obtains the highest praise from each customer. Our company has been devoting that "customer first" and committed to helping customers expand their business, so that they become the Big Boss !
By Gary from Mexico - 2018.09.29 17:23
Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
By Megan from Jamaica - 2017.01.28 18:53