Quad Output 5V3A&12V3A&-12V2A&24V3A 150W Power supply
Huyssen Quad Output Power Supply 150W
Universal AC input: 90-264V
Protections: Short circuit / Overload / Over voltage / over current
Cooling by free air convection
High efficiency, long life and high reliability
All using 105°C long life electrolytic capacitors
High operating temperature up to 70°C
LED indicator for power on
100% full load burn-in test
24 months warranty
Specifications:
OUTPUT | ||||||||||||
Model |
Q-150A |
Q-150B |
Q-150C |
|||||||||
Output number |
CH1 |
CH2 |
CH3 |
CH4 |
CH1 |
CH2 |
CH3 |
CH4 |
CH1 |
CH2 |
CH3 |
CH4 |
DC Voltage |
5V |
12V |
-5V |
-12V |
5V |
15V |
-5V |
-15V |
5V |
12V |
24V |
-12V |
Rated Current |
5A |
5A |
4A |
4A |
3A |
4A |
3A |
4A |
3A |
3A |
3A |
2A |
Rated Power |
150W |
150W |
150W |
150W |
150W |
150W |
150W |
150W |
150W |
150W |
150W |
150W |
Ripple & Noise |
100mVp-p |
120mVp-p |
100mVp-p |
120mVp-p |
100mVp-p |
120mVp-p |
100mVp-p |
120mVp-p |
100mVp-p |
120mVp-p |
150mVp-p |
120mVp-p |
Voltage Adj. Range |
CH1: -5%, +10% |
CH1: -5%, +10% |
CH1: -5%, +10% |
|||||||||
Voltage Tolerance |
±2% |
±6% |
±5% |
±5% |
±2% |
8% |
±5% |
±5% |
±2% |
±6% |
8% |
±5% |
-4% |
-4% |
|||||||||||
Setup,Rise,Hold Up Time | 1600ms,20ms,12ms/115VAC800ms,20ms, 60ms/230VAC at full load | |||||||||||
INPUT | ||||||||||||
Voltage Range | 90~264VAC47-63Hz; 120~370VDC | |||||||||||
AC Current | 2A/115V 0.8A/230V | |||||||||||
Efficiency |
75% |
78% |
80% |
|||||||||
Inrush Current | Cold start 18A/115V36A/230V | |||||||||||
Leakage Current | <1mA/240VAC | |||||||||||
PROTECTION | ||||||||||||
Over Load | 105%~150%/115VAC | |||||||||||
Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed | ||||||||||||
Over Voltage | 115%~135% | |||||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||||
ENVIRONMENT | ||||||||||||
Working Temp., Humidity | -10ºC~+60ºC; 20%~90%RH | |||||||||||
Storage Temp., Humidity | -20ºC~+85ºC; 10%~95%RH | |||||||||||
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||||||||||
SAFETY | ||||||||||||
Withstand Voltage | I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC | |||||||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||||||||||
STANDARD | ||||||||||||
EMC Standard | Design refer to EN55022,EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204 | |||||||||||
OTHERS | ||||||||||||
Dimension | 160*98*40mm(L*W*H) | |||||||||||
Weight | 0.6Kg | |||||||||||
Packing | 30pcs/ 19Kg | |||||||||||
NOTE | ||||||||||||
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. | ||||||||||||
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wire terminated with a 0.1μ &47μparallel capacitor. | ||||||||||||
3.Tolerance: includes set up tolerance, line regulation and load regulation. |
Applications:
Widely used in: Industrial control equipment, self-service terminal equipment, medical equipment, communication equipment, animation products, game consoles, beauty equipment,
Billboards, LED Lighting ,Display screen, 3D Printer, etc.